50-2500kVA/35kV Oil Immersed Double Winding Transformer
2025-01-26 05:39  Visit:294
Price:Unfilled
Brand:S9
Send inquiry
Product Overview
 

 

The S9 50-2500kVA/35kV three-phase oil-immersed transformer, developed by our company in response to market demands, features a special combination of capacity and voltage rating. It demonstrates a 30% reduction in no-load loss compared to conventional models based on actual measurements, with operating noise reduced by 4 decibels and temperature rise index controlled below K65. This transformer combines industrial-grade energy efficiency with lifecycle cost advantages. Its core is made of high-quality cold-rolled silicon steel sheets, while the high-voltage windings are constructed with high-quality oxygen-free copper wire arranged in a multi-layer cylindrical structure. All fasteners undergo special anti-loosening treatment processes to ensure structural integrity.

 

 

 

Type And Meaning
 

 

 

 

 

Application Scope
 

 

1. Normal use Environment: Elevation less than 1000m;Temperature Range:-25℃--+45℃
2. Especial Environment: Elevation more than 1000m;Temperature Range:-45℃--+40℃
3. Opposite air humidity: ≤90℃(+25℃)
4. Installation Site: Nothing corrodent air,noting obvious dirty mark
5. The product are used for lighting and deliver power in industry and agriculture

 

 

 

Executive Standards
 

 

GB1094.1~2-1996

GB1094.4-2005

GB1094.3, 5-2003

GB/T6451-2008

 

 

 

Product Features
 

 

1. The products which function reach international advance level of 2000 years are reformed for material, technics, structure.
2. They have a characteristic of high efficiency and low-loss, which save much electric loss and cost, improve society benefit.
3. The iron corn of product is made of high grade silicon steel, vacuum molded oil.
4. The radiator modality has ripple type, patch type, pipe type. Customer can choose freely the type.
5. The housing achieves an IP55 rating for dust and water resistance.

 

 

 

Main Technical Parameters
 

 

Rated

Capacity

(kVA)

Voltage

Marks

No-Load

Loss

(W)

On-Load

Loss

(W)

Short

cirait-z

(%)

No-Load

Cur

(%)

Weight(kg)

Size(mm)

Distance

(mm)

V

(kV)

Chng

(%)

V

(kV)

Wain w.t

Oil w.t

Ttl w.t

L·W·H

50

35

±5%

0.4

Yyn0

Or

Dyn11

210

1210/1270

6.5

2.0

230

270

700

1030×850×1460

550×550

100

290

2020/2120

1.8

370

320

950

1080×935×1580

550×550

125

340

2380/2500

1.7

440

350

1090

1100×940×1610

550×550

160

360

2830/2970

1.6

530

380

1120

1120×1035×1630

550×550

200

430

3330/3500

1.5

600

410

1340

1150×1050×1670

660×660

250

510

3960/4160

1.4

690

450

1520

1450×1130×1700

660×660

315

610

4770/5010

1.4

800

490

1730

1885×910×1720

660×660

400

730

5760/6050

1.3

920

540

1960

1950×1010×1820

660×660

500

860

6930/7280

1.2

1060

590

2210

2010×1070×1860

660×660

630

1040

8280

1.1

1460

620

2510

2100×1180×1960

660×660

800

1230

9900

1.0

1520

670

2940

2170×1260×2060

820×820

1000

1440

12150

1.0

1890

990

3910

2200×1690×2120

820×820

1250

1760

14670

0.9

2100

1090

4590

2230×1710×2250

820×820

1600

2120

17550

0.8

2820

1150

5150

235O×2020×2330

820×820

2000

2720

19350

0.7

2950

1200

5360

2600×2120×2350

820×820

2500

3200

20700

0.6

3350

1290

5870

2620×2220×2470

1070×1070

 

Note:
1. Load loss in the table below the diagonal values for Dyn11 connection group of products.
2. Technical parameters of 35kV distribution transformer for large capacity, size and weight data, please contact us.
3. Can provide various voltage transformer, short circuit impedance, coupling mode according to the user demand.
4. Table weight and size data for reference only, are subject to change without notice.

 

 

 

FAQ
 

 

Q: What is the lead time for delivering a 2000 kVA oil-immersed transformer?

A: Normal within 15 days. It depends on detail items and quantity.Please contact us for details.

Q: How to get product quotation?

A: You can contact us anytime through the contact information on the website. You will receive our response within 24 hours.

Q: What after-sales services can I enjoy?

A: The transformer comes with a one-year warranty. Long-term online technical support is provided, along with customer training, and regular updates to maintenance manuals and technical guides.

Q: How long is the average lifespan of a transformer?

A: The lifespan ranges from 20 to 40 years, influenced by factors such as maintenance level, operating environment, and load conditions.

Q: If your factory is a parts processing plant, what transformer capacity is suitable?

A: The selection should be based on the facility size. Small-scale processing workshops can use a 150kVA transformer, while medium-sized manufacturing plants are generally recommended to install 500kVA transformers or higher.

Q: Do you have oil-immersed transformers and dry-type transformers in stock?

A: No, as transformers require customized parameters based on demand, we usually need to design them after receiving an order.

 

 

 